Common Questions
With spring pollen and ozone alerts, can our old ductwork handle a better air filter?
Addressing April pollen peaks and ground-level ozone risk requires enhanced filtration, typically a MERV-13 filter. Your existing fiberboard and flex duct system may have high static pressure. Installing a high-MERV filter in a restrictive system can starve the blower, causing frozen coils and reduced airflow. A technician should perform a static pressure test before upgrading filtration; often, sealing leaks and replacing collapsed flex duct is necessary to support healthy airflow and IAQ.
It gets hotter than 92 degrees here. Will a new AC unit still keep up?
The 92°F design temperature is an engineering calculation for sizing equipment to maintain 75°F indoors on all but the 1% hottest hours. Summer highs exceeding this are expected, and a properly sized 3-ton unit will run continuously during those peaks. Modern systems using R-454B refrigerant maintain stable pressure and capacity better than older R-22 units in extreme heat. Correct sizing via a Manual J load calculation is critical to avoid short-cycling and ensure comfort.
We use electric heat strips now. Is a heat pump a good idea for Aberdeen's winters?
Switching from electric resistance heat to a cold-climate heat pump is highly advisable. While our winter lows are moderate, a heat pump can deliver heat at 2-3 times the efficiency of heat strips, drastically reducing winter electric bills. During the utility peak hours of 2 PM to 7 PM, the heat pump's efficiency advantage is most financially impactful. The existing HEEHRA rebates make this transition more accessible than ever for electric-heat homes.
Our AC just quit on a hot day in Downtown Aberdeen. How quickly can a technician get here?
A no-cool call from the Aberdeen Historic District is a priority dispatch. Our service vehicles are typically staged near US Highway 45, allowing for a 5 to 10 minute response to most downtown addresses. The first diagnostic step on arrival is to check for a tripped breaker or a clogged condensate drain, two common and often quickly resolved failure points in this climate.
What are the rules for installing a new system with the newer, safer refrigerant?
All installations in the City of Aberdeen require a permit from the Aberdeen Building Department. Since January 2023, new residential equipment uses lower-GWP A2L refrigerants like R-454B, which are mildly flammable. 2026 codes mandate specific safety standards for these refrigerants, including leak detectors, revised service port placements, and updated labeling. Only EPA-certified technicians following these protocols can legally handle and install this new class of refrigerant.
Our house is from the 1970s and the AC unit is original. Should we be worried about indoor air quality?
An average Aberdeen home built in 1971 has a system that is over 55 years old. Original fiberboard ducts and evaporator coils from that era are now porous and compromised. The humid subtropical climate creates a constant moisture load, making these aging components a primary site for microbial growth. This often manifests as musty odors and reduced cooling capacity, signaling it's time for a full system assessment.
Our Ecobee thermostat is showing an 'E1' alert. What does this mean for our system?
An Ecobee E1 alert indicates the thermostat is not detecting a call for cooling or heating from your HVAC equipment. In Aberdeen's humidity, this often points to a safety lockout on the control board due to a flooded evaporator coil or a faulty pressure switch. It's a specific signal that the system has encountered an operational fault and shut down to prevent compressor damage, requiring a technician to diagnose the root cause, which is frequently related to the high moisture load.
We heard about new efficiency rules and a federal rebate. What does this mean for our electric bill?
As of 2026, all new central air conditioners installed in Mississippi must meet a minimum 14.3 SEER2 rating. Upgrading from a legacy 8 or 10 SEER unit to a modern 16+ SEER2 system can cut cooling energy use by over 40%. With local utility rates at 11 cents per kWh, the savings are significant. The Inflation Reduction Act's HEEHRA rebates, with an $8,000 cap for qualified heat pump installations, directly offset this higher-efficiency equipment's upfront cost.